1. Home
  2. Commercial & industrial
  3. Self-storage

Commercial · Self-storage

Self-storage buildings

A clear-span shell with tall eaves, so you can lay out storage units across two floors and change the mix as demand changes.

  • 18–30 mspans
  • 7–9 meaves
  • 1–2floors
  • Freefirst design
3D render: Self-storage building

Typical 24 × 36 m self-storage building

864 m² · supply and erect from £332/m²

KitSupply only, with erection drawingsFrom £221,000
Supply and erectThe building, plus installationFrom £287,000
TurnkeyPlus foundations, slab, lighting and powerFrom £427,000

All prices exclude VAT. Guide prices. Delivery is priced separately. Itemised written quote after a site survey. Cost guide →

The example shown

What this example includes

This is the building in the picture and the guide prices above. Every item can be changed in the 3D designer.

  • Clear-span steel frame24 m wide with no posts inside · 7 frames
  • Size24 × 36 m · 864 m² · 8 m to the eaves
  • Gable door4 m wide × 4.5 m high
    x1
  • Side doors4 m wide × 4.5 m high each
    x2
  • Walk-through doorsFor people, separate from the vehicle doors
    x2
  • Insulated walls and roof80 mm PIR insulated panels
  • ColoursWalls: White aluminium, RAL 9006Roof: White aluminium, RAL 9006Trims: Gentian blue, RAL 5010
  • Mezzanine floorAbout 432 m² (50% of the floor), sourced for you
  • Fire protectionIntumescent coating on the steel frame
  • Design and drawingsDesigned for the wind and snow at your site, with a foundation plan

Delivery and installation are not included in the building price; each is priced separately. What is in the price, and what is not →

Ready-made

Enquire about this building

Self-storage building, 24 × 36 m, as shown. Nothing to design.

Rough cost, excluding VATFrom £221,000The building only (kit)

All prices exclude VAT. We reply with an itemised quote. Your details are used only to reply. Privacy

Before you design

Planning a self-storage building: decide these first

  1. Decide the unit mix firstThe sizes of the units you want to let set the frame spacing and where the corridors run.
  2. Drive-up or indoor unitsDrive-up units need many doors and a wide yard. Indoor units need corridors, and lifts if there is an upper floor.
  3. Mezzanine floorsAn upper floor multiplies the lettable space. It also needs stairs, a goods lift and a fire strategy, so plan it at the start.
  4. Dry airCustomers' goods need a dry building. Insulated panels and steady ventilation prevent condensation.
  5. Security and lightingGates, cameras and lighting are part of the product. Outside lighting can be a planning matter near homes.
  6. Build in phasesThe frame can be designed so you add bays as the units fill.

More detail

The details

What this building does
  • Free unit layout

    No internal columns in the way, so unit partitions can go anywhere and move later.

  • Two floors of units

    A mezzanine across half the building doubles the lettable area on the same footprint.

  • Fire protection

    Intumescent coating on the frame and fire-rated walls where the layout needs them.

  • Easy loading

    Loading doors at the side and gable, close to the lift and stairs.

Typical specification

24 × 36 m self-storage building

Size
24 m span × 36 m long, to the steel line
Outside the cladding
24.45 × 36.45 m
Floor area
864 m²
Eaves height
8 m to the steel line
Height to ridge
9.57 m to the top of the roof
Clear inside
22.79 m between columns, about 7.2 m under the haunches
Roof pitch
6°
Frames
7 frames, 6 bays at 6.00 m centres
Cladding
80 mm PIR insulated panels
Colours
Walls RAL 9006 White aluminium · roof RAL 9006 White aluminium
Side doors
2 × 4 m wide × 4.5 m high
Gable doors
1 × 4 m wide × 4.5 m high
Personnel doors
2
Windows
None
Rooflights
None
Mezzanine
50% of floor, about 432 m²
Fire protection
Intumescent coating

This is the starting point in the 3D designer. Every item can be changed.

What every building comes with

Every building is designed for the wind and snow at your site, and comes with a foundation plan for your groundworker and an itemised written quote for the option you choose: kit, supply and erect, or turnkey. Delivery and installation are not included in the building price; each is priced separately.

What is in the price, and what is not →

Size it by lettable area

A mezzanine floor adds lettable area without adding footprint.

FacilityTypical sizeEavesFloors
Small rural facility15 × 24 m5 m1
Town facility24 × 36 m8 m2 (50% mezzanine)
Large facility30 × 48 m9 m2
Container-plus-building site18 × 30 m6 m1

Guide sizes only. Unit partitions and lifts come from your storage fit-out supplier.

What changes cost

Estimated change from the typical building above, supply and erect, ex VAT. Worked out with the same model as the 3D designer.

  • Increase the mezzanine to 60%More units upstairsfrom +£16,500
  • Lengthen to 42 mOne more 6 m bayfrom +£40,000
  • Switch to mineral wool panelsNon-combustible walls and rooffrom +£41,000
  • Add a third loading doorAnother loading pointfrom +£4,500
  • Go turnkeyWe add foundations, slab, lighting and powerfrom +£132,500
Try it in 3D. The designer opens this building with a 50% mezzanine. Change the mezzanine size and watch the estimate move.
Open in the 3D designer
Common questions
How much does a mezzanine add?

It roughly doubles the lettable area of the part of the building it covers, for much less than the cost of a bigger footprint.

Do you fit the storage units?

No. We build the shell and source the mezzanine and stairs. Your storage partition supplier fits the units and doors.

Does self-storage need fire protection?

Often, because of the upper floor and the public using the building. We design the fire strategy with building control.

More advice and FAQs →

Planning and rules, in brief

  • Planning permission. Most new buildings need it. Your council decides.
  • Building Regulations. Almost every new building needs approval. Building control checks the structure, fire safety and, in heated buildings, the insulation.
  • The frame. Designed by a structural engineer to Eurocode 3, for the wind and snow at your site.

A guide for England, not legal advice. The rules we design to →

Design your self-storage building